General Data | |
Standard | IEC/EN 61008-1, IEC/EN 62955 |
Protection | Ground fault |
Type of trip | Electro-magnetic type |
Residual current type | Type A + DC 6mA |
Claasification of RDC-DD | RDC-PD |
No. of poles | 1P+N, 3P+N |
Insulation voltage (Ui) | 500V |
Rated voltage (Ue) | 1P+N: 240V~; 3P+N: 415V~ |
Rated currents (In) | 16, 25, 32, 40, 63A |
Rated sensitivity current (IΔn) | 30mA |
Rated residual operating current (IΔdc) | 6mA |
Residual current off-time under (IΔn) | ≤0.1s |
Rated residual making and breaking capacity (IΔm) | 500A (In≤50A), 10In (In>50A) |
Rated frequency | 50/60Hz |
Rated conditional short-circuit current (Inc=IΔc) | 10kA |
Rated impulse withstand voltage (Uimp) (1.2/50μs) | 4kV |
Dielectric test voltage | 2kV (50/60Hz, 1min.) |
Electrical life | 2,000 Cycles |
Mechanical life | 4,000 Cycles |
Contact position indication | green OFF / red ON |
Ground fault indicator | White: Normal; Red: Leakage fault |
Protection degree | IP20 |
Ambient temperature | -25°C ~ +55°C, Max.95% humidity |
Terminal connection type | Cable/ Pin-type/ Fork-type busbar |
Max. terminal size for cable | 35mm² |
Max. tightening torque | 2.5N.m |
Mounting type | Mounting on 35mm DIN rail |
Incoming method | Bi-Directional |
Tripping Sensitivity | |
30mA | This is the most commonly used protection level in homes and commercial buildings, and is suitable for socket protection in general residential environments, offices and commercial places. |
DC 6mA | Designed to detect DC leakage currents of 6 mA or greater. When such a leakage current is detected, the protection device will interrupt the circuit to prevent potential hazards such as electric shock or fire. |
Tripping Characteristic | ||
Maximum values of break times for residual direct currents | ||
Standard values of maximum break time at a residual direct current equal to (s) | ||
6mA | 60mA | 200mA |
10 | 0.3 | 0.1 |
Minimum values of non-operating time for alternating residual currents (RMS values) | |||
Minimum values of non-operating time (s) in event of alternating residual currents (RMS values) equal to | |||
up to 30mA | 60mA | 150mA | 5A |
no tripping | 0.3 | 0.08 | 0.08 |