ETEK Reliable 100A B Type RCCB EKL6-100B Residual Current Circuit Breaker
Product Details
| Customization: | Available |
|---|---|
| Breaking Capacity: | Low Voltage Circuit Breakers |
| Operation: | Manual Type |
Shipping
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
Payment Guarantee
| Payment Methods: |
|
|---|---|
| Support payments in USD |
| Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
|---|
| Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
|---|
Manufacturer/Factory & Trading Company
360° Virtual Tour
Secured Trading Service
Diamond Member Since 2025
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Importers and Exporters
High Repeat Buyers Choice
100% Finished Products Inspection
OEM Services
The supplier has import and export rights
More than 50% of buyers repeatedly choose the supplier
The supplier inspects 100% of finished products.
The supplier provides OEM services for popular brands
Sign In to see all verified strength labels (25)
Find Similar Products
Basic Info.
- Model NO.
- EKL6-100B
- Speed
- Normal Type Circuit Breaker
- Arc-extinguishing Medium
- Air
- Installation
- 35mm DIN Rail
- Structure
- RCCB
- Poles Number
- 1p+N, 3p+N
- Type
- Circuit Breaker
- Function
- Overcurrent Protection, RCCB, Short Circuit Protection
- Certification
- CE, CB, Ukca, TUV
- Type of Trip
- Electro-Magnetic
- Rated Breaking Capacity
- 10ka
- Standard
- IEC61008-1/IEC62423/VDE0664-400
- Residual Current Type
- B, Bhp, B+
- Transport Package
- Carton
- Specification
- 47.5*25.5*25.5
- Trademark
- ETEK / OEM
- Origin
- Zhejiang, Prc
- HS Code
- 8536200000
Packaging & Delivery
- Package Size
- 47.50cm * 25.50cm * 25.50cm
- Package Gross Weight
- 21.060kg
Product Description
Product Description
EKL6-100B Residual Current Circuit Breaker
EKL6-100B Type B Residual Current Circuit Breaker (RCCB) suitable for 110/230/240V (1P+N) or 240/400/415V (3P+N) power systems, with a rated current up to 100A. Designed to detect AC leakage currents, pulsating DC leakage currents, smooth DC leakage currents, composite waveform leakage currents, and high-frequency leakage currents up to 1kHz. When human electric shock occurs or circuit leakage current exceeds specified values, the circuit breaker instantaneously disconnects the faulty power supply to protect personnel and electrical equipment. It can also serve for infrequent circuit switching operations under normal conditions.


1. Comprehensive Protection
From basic overcurrent to sophisticated arc fault detection, ETEK products provide complete circuit protection in one cohesive product family.
2. Certified Quality
Meets or exceeds international standards with certifications including CE, VDE, TUV, CB, and more.
3. Universal Compatibility
Compatible accessories and uniform design across the entire range enable seamless integration in distribution panels.
4. Installation Friendly
Designed with installer needs in mind, featuring clear terminals, easy access points, and compatibility with standard DIN rail systems.

Certifications



Techinical Data
General Data | |
Standard | IEC/EN 61008-1, IEC/EN 62423 |
Protection | Ground fault |
Type of trip | Electro-magnetic type |
Residual current type | B Type - residual AC, pulsating and smooth DC current, high frequency (≤1kHz) |
Time characteristic | Instantaneous |
No. of poles | 1P+N, 3P+N |
Neutral | Switched, N pole on the right |
Insulation voltage (Ui) | 500V |
Rated voltage (Ue) | 1P+N: 110/230/240V~; 3P+N: 240/400/415V~ |
Rated currents (In) | 1P+N: 16, 25, 40, 63A (80, 100A (3modules)); 3P+N: 16, 25, 40, 63, 80, 100A |
Rated sensitivity current (IΔn) | 30, 100, 300mA |
Rated current off-time under (IΔn) | ≤0.1s |
Rated residual making and breaking capacity (IΔm) | 500A (In≤50A), 10In (In>50A) |
Rated frequency | 50/60Hz |
Rated conditional short-circuit current (Inc=IΔc) | 10kA |
Rated impulse withstand voltage (Uimp) (1.2/50μs) | 4kV |
Dielectric test voltage | 2.5kV (50/60Hz, 1min.) |
Electrical life | 2,000 Cycles |
Mechanical life | 4,000 Cycles |
Contact position indication | green OFF / red ON |
Ground fault indicator | White: Normal; Red: Leakage fault |
Protection degree | IP20 |
Ambient temperature | -25°C ~ +40°C, Max. 95% humidity |
Terminal connection type | Cable/ Pin-type/ Fork-type busbar |
Max. terminal size for cable | 35mm2 |
Max. tightening torque | 2.5N.m |
Mounting type | Mounting on 35mm DIN rail |
Incoming method | Bi-Directional |
Tripping Sensitivity | |
30mA | This is the most commonly used protection level in homes and commercial buildings, and is suitable for socket protection in general residential environments, offices and commercial places. |
100mA | Usually used in situations where personal protection requirements are not as strict as 30mA, or for equipment protection such as air conditioning systems, industrial equipment, etc. |
300mA | Mainly used for fire protection, such as distribution boards and the general protection of large electrical equipment. |
Tripping times | |||||
Type B RCDs - Standard values of break me and non-actuating time for residual direct currents which result from rectifying circuits and for residual smooth direct current. | |||||
Type | Fault currents | Tripping time at | |||
Alternating currents | 1×IΔn | 2×IΔn | 5×IΔn | 500A | |
Pulsating DC currents | 1.4×IΔn | 2×1.4×IΔn | 5×1.4×IΔn | 500A | |
Smooth DC currents | 2×IΔn | 2×2×IΔn | 5×2×IΔn | 500A | |
Standard | Max. 0.3s | Max. 0.15s | Max. 0.04s | Max. 0.04s | |
Type B RCDs - Residual non-opera ng and opera ng current according to frequencies which differ from the rated frequency 50/60 Hz | ||
Frequency (Hz) | Residual non-operating current (IΔn) | Residual operating current (IΔn) |
150 | 0.5 IΔn | 2.4 IΔn |
400 | 0.5 IΔn | 6 IΔn |
1000 | IΔn | 14 IΔn |

Wiring Capacity | ||
Rated current In (A) | Cross-sectional areas (mm2) | Tightening torque (N,m) |
16 | 2.5 | 2.5 |
25 | 4 | 2.5 |
32 | 6 | 2.5 |
40 | 10 | 2.5 |
63 | 16 | 2.5 |
80 | 25 | 2.5 |
100 | 35 | 2.5 |

Packaging & Shipping




After Sales Service

Quality Assurances
Online Support
Techinical Team Support
For the product you have purchased, we offer a three-year replacement warranty to safeguard your after-sales rights.
For any product issues you encounter after purchase, our after-sales team will respond promptly and provide you with support.
For relatively complex product problems, we also have a professional technical team available to offer assistance and advice.
About Us


ETEK Electric
ETEK Electric specializes in the manufacturing of low-voltage electrical appliances. Currently, our production facility spans an area of 10,000 square meters, with an annual output exceeding 8 million poles of MCBs.
Founded in 2011, we bring over 14 years of industry experience. In 2018, we achieved automation across multiple production lines. By the end of 2023, we completed the construction of our new manufacturing base — ETEK Electric (Wuhu) Co., Ltd., located in Anhui Province.
Our factory holds ISO9001, ISO14001, and ISO45001 certifications, while our products are certified with CE, CB, TUV, UKCA, SEMKO, VDE, SAA, among others. Our products are exported to more than 100 countries and regions, including the UK, France, Australia, Russia, Ukraine, Turkey, and Brazil.
Founded in 2011, we bring over 14 years of industry experience. In 2018, we achieved automation across multiple production lines. By the end of 2023, we completed the construction of our new manufacturing base — ETEK Electric (Wuhu) Co., Ltd., located in Anhui Province.
Our factory holds ISO9001, ISO14001, and ISO45001 certifications, while our products are certified with CE, CB, TUV, UKCA, SEMKO, VDE, SAA, among others. Our products are exported to more than 100 countries and regions, including the UK, France, Australia, Russia, Ukraine, Turkey, and Brazil.



Our Partners & Exhibitions





FAQ
1. Are you a factory?
Yes, we are not only the manufacturer but also the direct sales company affiliated with the factory.
2. May I request free samples?
We will provide a certain number of free samples according to your actual purchasing demand.
3. What certification do you have?
Our certifications include CE, CB, TUV, UKCA, SEMKO, VDE, SAA, etc.
4. If there are any quality issues, how do you solve them?
You can directly contact the sales representative assigned to you,
who will communicate with you to identify specific quality issues and provide solutions.
5. How long is the delivery time?
Normally, the delivery time ranges from 15 to 30 days.
6. Can you provide us with the testing report?
If necessary, we can also provide test reports for the products.
Send your message to this supplier
People who viewed this also viewed
Find Similar Products By Category
- Supplier Homepage
- Products
- RCCB
- B Type
- ETEK Reliable 100A B Type RCCB EKL6-100B Residual Current Circuit Breaker
Related Categories
Hot Searches
- Circuit Breaker Factories
- Vacuum Circuit Breaker Factories
- Electrical Circuit Breaker Factories
- Air Circuit Breaker Factories
- Fixed Circuit Breaker
- Used Circuit Breaker
- Custom Circuit Breaker
- Protector Circuit Breaker
- Auto Circuit Breaker
- Circuit Breaker Trends
- Residual Current Circuit Breaker Bulkbuy
More